Skip to content

RENOWELL · ENGINEERING

Engineering tools

Estimate a pump operating point or prepare a replacement inquiry. Your entries stay in this tab.

RENOWELL · A

Hydraulic workbench

Estimate flow, power and steady shaft load, then compare two operating points.

Efficiency varies with operating conditions; leave it blank if unknown. Assumptions are not test results. Enter the required flow at the pump outlet, with circuit losses included only where assessed by the equipment engineer.

Scenario A

Displacement
Actual pump-shaft speed
Pump pressure difference ΔpOptional · leave blank if unknown
Volumetric efficiency ηvOptional · leave blank if unknown
Mechanical efficiency ηmOptional · leave blank if unknown

More information needed

Enter the required inputs to calculate a scenario.

Missing / unconfirmed: Displacement · Actual pump-shaft speed

Use these estimates for initial discussion. Confirm model ratings, inlet conditions, fluid compatibility, starting loads and motor thermal limits with Renowell and the equipment engineer before selection or installation.

Use pump outlet pressure minus inlet pressure, at the same operating point. Load pressure elsewhere in the circuit is not necessarily this difference.

Sources & method

Source content checked 2 October 2026 · recheck due 2 April 2027

These references explain the formulas. Their product ratings do not apply to Renowell pumps.

Q₀ = Dn/1000 · Q = Q₀ηv · Ph = ΔpQ/600 · Ps = Ph/(ηvηm) · T = ΔpD/(20πηm). D in cm³/rev, n in rpm, Δp in bar, Q in L/min.

Calculation scope: displacement ≤ 10,000 cm³/rev, flow ≤ 30,000 L/min, shaft speed ≤ 30,000 rpm and pressure difference ≤ 1,000 bar. These are software scope limits, not permissible pump operating limits. No universal design margin is applied.

Includes your inputs, assumptions, missing details and formula references. After editing, copy or print the updated brief.

Calculation / inquiry brief

Review and submit on the next page. Stay in this tab: refreshing clears the brief and selected files.

RENOWELL · B

Replacement brief

Gather the model, connections and operating conditions for a replacement inquiry.

Before ordering, confirm the full model, drawings, operating limits and availability with Renowell. A completed checklist does not confirm interchangeability.

Enter the recorded value, drawing reference, or leave blank if unknown.

More information needed

Continue to inquiry and ask for help with the missing details.

Missing / unconfirmed

  • Original manufacturer
  • Complete model code
  • Rotation designation
  • Viewing direction for rotation
  • Shaft profile & dimensions
  • Mounting flange / pilot / bolt pattern
  • Port sizes, standards & orientation
  • Fluid product / grade
  • Actual pump-shaft speed
  • Operating pressure, peaks & duration
  • Quantity required
  • Pump arrangement

Before ordering, confirm the full model, drawings, operating limits and availability with Renowell. A completed checklist does not confirm interchangeability.

Sources & method

Source content checked 2 October 2026 · recheck due 2 April 2027

Includes your inputs, assumptions, missing details and formula references. After editing, copy or print the updated brief.

Calculation / inquiry brief

Review and submit on the next page. Stay in this tab: refreshing clears the brief and selected files.

Entries stay in this tab. Reloading or leaving clears them.